Mechanical:____________________________________________________________________________________
Enclosure size:
HubMax: 16”h x 19”w x 4”d
MiniMax: 11.5”h x 11.5”w x 3.75”d
HubMax Electrical:_______________________________________________________________________________
Input: 16.5VAC +/- 10% 20VA – Includes Transformer
Battery Circuit Output: 13.8VDC typical, 7.2 Ah max., 1Ah min.
Battery Charge Type: Float
AC Ripple: 50mV P-P
MiniMax Electrical:_______________________________________________________________________________
Input: 16.5VAC +/- 10% 20VA – Includes Transformer
Accessory Device Circuit Output: 13.8 VDC typical, .5A max., 1AH Battery min*
Battery Circuit Output: 13.8VDC typical, 6AH Battery max., 1AH min.
Locking Device Circuit Output: 13.8 VDC typical, 16.5 VAC 1A max*
Battery Charge Type: Float
AC Ripple: 50mV P-P
*Total current drain for all outputs should not exceed 1Amp
Wiring Requirements:_____________________________________________________________________________
Maximum Distances with shielded: 18 AWG 20 AWG 22 AWG
Controller to reader/keypad 1000’ 500’ 250’
Controller to controller 1000’ 500’ 250’
Controller to PC or Printer 1000’ 500’ 250’
Outputs:________________________________________________________________________________________
RS-232 ports for printing and networking functions.
DCM Main Lock Relay: SPDT 2 amps @ 24VDC.
DCM Forced Door, Propped Door, Alarm Shunt Relays: SPDT 1 amp @ 24VDC.
Environmental:__________________________________________________________________________________
Operating temperature: -20° F to 130°F (-28°C to 54°C)
Hub Manager Professional Minimum System Requirements:_______________________________________________
• 486 or higher processor
• Microsoft Windows
®
98/2000/XP
• 12 MB RAM
• CD ROM drive (for installation)
• Monitor: VGA or higher
• Modem: IEI qualified modem for remote applications
Qualified PC Modems: _________________________ _____________________________________
• Boca 14.4k External, Model M144OE
• Boca 33.6k External
• US Robotics 33.6k External, Model 000839-09
• US Robotics 56k External, Model 005686-03
Specifications
Cards & Tokens
Prox Cards
DuoProx II – Prox plus
Magstripe technology
ProxCard II
ISOProx II – Same size
as credit card
ProxKey II – Prox key fob
Mag Cards
MagCrd – 10 (10 pack)
MagCrd – 25 (25 pack)
MagCrd – 100 (100 pack)
Touch Chips
TchChp – 10 (10 pack)
TchChp – 25 (25 pack)
TchChp – 100 (100 pack)
MiniMax
II
Secured Series
Systems Overview
The MiniMax features the IEI Door Control Module (DCM)
preinstalled on the backplane and contains a power supply for
readers as well as for the door strike or magnetic lock (AC or DC).
The MiniMax is ideal for applications where the control is installed
at the door (e.g. above the ceiling over the door). The MiniMax is
designed for simplicity and to provide a clean and easy installation.
MiniMax includes Hub Manager Professional software.
HubMax is designed as a modular Access Control System in one
or more sites. You can start as a single-door system and then
easily plug in Door Control Modules to create a perfectly tailored
access control system. Each HubMax comes complete with a
HubMax backplane, programming keypad, mounting enclosure
and single HubMax Door Control Module. The backplane
provides expansion slots for three more Door Control Modules
allowing for up to four Door Control Modules; as needs demand.
The HubMax can be networked with other controllers to create
the ultimate flexibility in system design. HubMax includes Hub
Manager Professional software.
HubMax
II
The IEI prox.pad plus is a fully integrated single door
access system with advanced capabilities for networking
up to 32 doors per site. This latest addition to the IEI
Access System product line allows for diverse network
application solutions when using Hub Manager
Professional and Secure Ethernet Gateway.
Fast mounting local controller
eliminates costly wire runs
Integrated HID proximity reader
can be mounted up to 10' from
controller
Audit trail, time zones, unlimited
sites and holiday scheduling
Can use existing LAN/WAN
wiring or proprietary 485 network
prox.pad
Plus
Integrated Access System
• Grade 1 Locksets
• Non-volatile eeprom memory allows
in-shop programming
• One non-handed unit for indoor
and outdoor application
Wire raceway provides clean installation
and protects wires inside door
• Programs the same as all IEI products
LS Series
Access Control Locksets
Two stage low battery alert assures entry
• Propped door and forced door alerts when used with
a standard magnetic switch
• Request to exit allows door to be unlocked remotely
• Four standard AA batteries provide up to 150,000 operations
• LS-2: IR Communication to
Hub Manager Professional
Software via hand held device
• LS-2P: Adds higher security
with Proximity Reader
Available in:
Cylindrical
Mortise
Exit
Mortise w/ Deadbolt
Vista de pagina 2