INSTALL & ACTIVE MODE SYSTEM DISPLAYS
SpotCell Viewer 2 9
Note: In the case of the SpotCell 100 unit that operates in the 800 MHz cellular band,
the Start and Stop Frequencies and Bandwidth are replaced by the Cellular Band (A or
B) that is pre-programmed into the unit at the factory.
Coverage Unit Display
Replicates the messages shown on the LCD display located on the bottom edge
of the Coverage Unit.
4.1.2 Adaptive System Parameters
Active Base Station
Received Isotropic Power displays the level of the base-station channel selected
by the adaptive algorithm. The signal level is displayed in dBm referenced to the
Donor Unit antenna input.
Frequency displays the base-station frequency selected by the adaptive
algorithm.
Current Channel Number displays the base-station channel number selected by
the adaptive algorithm.
Protocol displays the base-station protocol.
Out of Band Signal
Maximum Received Isotropic Power displays the level of the highest received out
of band signal. In the case of the SpotCell 111 & SpotCell 112 the entire band
outside of the start and stop frequencies is scanned and the strongest signal
level indicated in this field. For the SpotCell 100, which operates in the cellular
band, the unit identifies the strongest signal in the alternate band (e.g., if the unit
is configured for the A band then the strongest B band signal is shown). The
signal level is in dBm referenced to the Donor Unit antenna input.
Frequency identifies the frequency of the highest out of band signal.
Adaptive System Gains
Not available when the SpotCell is in install mode.