TECHNICAL REFERENCE
8-29
Register Default Function
S33 0 Bit-mapped register setup. To set the register, see the instructions for S13.
Bit Value Result
0 1 Disable 2400 symbol rate.
1 2 Disable 2743 symbol rate.
2 4 Disable 2800 symbol rate.
3 8 Disable 3000 symbol rate.
4 16 Disable 3200 symbol rate.
5 32 Disable 3429 symbol rate.
6 64 Reserved
7 128 Disable shaping.
S34 0 Bit-mapped register setup. To set registers, see instructions for S13.
Bit Value Result
0 1 Disable 8S-2D trellis encoding.
1 2 Disable 16S-4D trellis encoding.
2 4 Disable 32S-2D trellis encoding.
3 8 Disable 64S-4D trellis encoding.
4 16 Disable non-linear coding.
5 32 Disable TX level deviation.
6 64 Disable Pre-emphasis.